ME 26 DERIVE
"SIGNAL DRIFT"   AMPLIFIER

ME 26 INT "SIGNAL INTEGRATOR"   AMPLIFIER

Zero adjustment

 
Voltage integrator from +/- 1 mV to +/- 25V
Voltage differentiator from +/- 1 mV 
to +/- 25V
Accuracy and stability
Analogic output ± 10V or 0 -20 mA 
or 4 - 20 mA
Zero and gain adjustment
Electronic calibration simulator
Span adjustment
Calibration
Scale adjustment
Compatible with : 
- 2680C  multi-channels instrument, 
-
ME52 rail DIN mono-channel
- ME261B IP65 multi-channels.

 

APPLICATION AND CONNECTION

 

TECHNICAL FEATURES

Integration or Differentiation from 1 msec to 1 sec
(another range on request)
Inputs (admissible maximum ± 25V)
Others ranges on request until +/- 200 Vdc
Input voltage range : ± 10V
Asymmetric input impedance : 100 kOhm
Differential input impedance : 200 kOhm
Input current (option) 0 - 20 mA or 4 - 20 mA
Output voltage Maximum output voltage : ± 10V
Maximum output current : 5 mA
Maximum output impedance : 50 Ohm
Output voltage (option) 0 to 20 mA or 4 to 20 mA
Gain ranges Range I : from 1 to 5
Range II : from 5 to 25
Range III : from 25 to 125
Zero adjustment Fixed : 2 to 10% from the input range
Variable : from 3 to 15% from the input range
Calibration simulator 1V
Common mode rejection 100dB
Power supply variations rejection (± 2V) 100dB
Maximum noise in the input (White noise) 0.2mV peak to peak
Maximum noise in the input (with ME 26 ISO) 10mV peak to peak
Operating temperature 0°C to 50°C
Storage temperature -40°C to +70°C
Protection Against the short circuits
Power supply (Without charge in the output) 24 Vdc ± 2V, 25 mA
Option  RAL26EU 100 x 160 mm Europe  adapter DIN 41612 connector
Galvanic Insulation option with ME26ISO with ME 26 ISO extension card
Input / Output Insulation : 500 V
Input / Power supply Insulation:   500 V