THESE
CONDITIONERS MUST
BE INTEGRATED IN THE FOLLOWING INSTRUMENT BOX : - All of them in MEIRI 2680C - Short models in BOXES ME52, ME520, ME52C and ME261 ET ME261 B |
||||
|
Numéric |
|
Amplifiers Conditioners Analogic adjustement numérics |
Amplifiers Conditioners Analogic adjustement ANALOGICS |
FONCTION | APPLICATIONS |
|
|
|
Signal conditioner for transducer with strain gages | Load, Pressure, Torque... | ||
|
|
|
Signal conditioner for piezzoresistive transducer | Load, Pressure, Acceleration... | ||
![]() |
ME 26C Microstrain |
Amplifier for extensometry | Strain gages 1/4, 1/2 or Full bridge | ||
|
|
|
Signal conditioner for potentiometric transducers | Displacement, Position... | ||
|
|
|
Signal conditioner for LVDT transducers. | Displacement, Position... | ||
![]() |
![]() |
ME
26C-CO & ME 26C-CO-DYN |
ME 26 CO |
Convertor for incremental encoder / analogic output | Linear displacement, angle measuring |
![]() |
Frequency/Voltage or Voltage/Frequency Converter. | Frequency, Flow, Rotation | |||
![]() |
![]() |
ME 26C - ICP | ME 26 ICP | Signal conditioner for piezzoelectric transducers with integrated electronic ICP power supply (constant current) | Acceleration, Inclination, Pressure... |
![]() |
ME 26 PIEZO | Charges amplifier for piezzoelectric transducers (Quartz) | Load, Pressure, Acceleration | ||
|
|
ME 26 ACE-INC | Signal conditioner for transducers with integrated electronic | Acceleration, Inclination, Pressure... | ||
|
|
= |
Signal conditioner for RTD 100 or RTD 1000 thermal probes | Temperature | ||
|
|
|
Signal conditioner for J, K or T thermocouples | Temperature | ||
|
|
|
Summator
or Subtractor with N channels. |
Analogic calculations | ||
![]() |
ME 26 DÉRIVE / INT | Differentiator / Integrator Converter | Analogic calculations | ||
![]() |
ME 26C-U-INT | Differentiator / Integrator Converter | Analogic calculations | ||
|
|
|
Voltage amplifier | AC, DC voltage | ||
|
|
|
Current-Voltage / Voltage-Current / Current-Current Converter | U/U,
U/I, I/I, I/U AC ou DC |
||
|
|
ME 26 MV2 | Analogic fast peak memory | Load, Torque, Voltage... | ||
![]() |
ME 26C-MC-Fuite | Analogic fast peak memory | Load, Pressure, ... | ||
|
|
![]() |
ME 26C - 4 x SV2 | ME 26 SV2 et SV2 P | Double limits detector (Alarms) | SV2
= 2 Alarmes SV2 P = 2 Alarmes selon un Process |
![]() |
ME 26C-Filtre PB | ME 26134 V2 PB | Programmable Low Pass Active Filter | Measuring filtrage, Antialiasing | |
![]() |
ME 26134 V2 PH | Programmable High Pass Active Filter | Measuring filtrage | ||